Update Calibration
parent
82c163ee93
commit
35b2f96575
1 changed files with 4 additions and 4 deletions
|
@ -1,5 +1,5 @@
|
|||
Up vision calibration
|
||||
---------------------
|
||||
## Up vision calibration
|
||||
|
||||
part placed too far to the right?
|
||||
increase X camera position
|
||||
part placed too far to the left?
|
||||
|
@ -18,8 +18,8 @@ part measurement height too high?
|
|||
part measurement height too low?
|
||||
increase "Distance/Pixel" Y (second value)
|
||||
|
||||
Nozzle calibration
|
||||
------------------
|
||||
## Nozzle calibration
|
||||
|
||||
"NozzleDown"
|
||||
These values calibrate the 0mm depth, e.g. for the PCB this is the level of the PCB holder, the system will automatically add the PCB thickness
|
||||
|
||||
|
|