From 35b2f9657518b483376292e4c1155c892b42b9b9 Mon Sep 17 00:00:00 2001 From: Nicole Faerber Date: Tue, 24 Mar 2020 16:36:04 +0100 Subject: [PATCH] Update Calibration --- Calibration.md | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/Calibration.md b/Calibration.md index eb91f1e..5f6c4da 100644 --- a/Calibration.md +++ b/Calibration.md @@ -1,5 +1,5 @@ -Up vision calibration ---------------------- +## Up vision calibration + part placed too far to the right? increase X camera position part placed too far to the left? @@ -18,8 +18,8 @@ part measurement height too high? part measurement height too low? increase "Distance/Pixel" Y (second value) -Nozzle calibration ------------------- +## Nozzle calibration + "NozzleDown" These values calibrate the 0mm depth, e.g. for the PCB this is the level of the PCB holder, the system will automatically add the PCB thickness