## Up vision calibration
|
||||
|
||||
- part placed too far to the right?
|
||||
|
||||
- increase X camera position
|
||||
|
||||
- part placed too far to the left?
|
||||
|
||||
- decrease X camera position
|
||||
|
||||
- part placed too far to the back?
|
||||
|
||||
- increase Y camera position
|
||||
|
||||
- part placed too far to the front?
|
||||
|
||||
- decrease Y camera position
|
||||
|
||||
- part measurement width too high?
|
||||
- decrease "Distance/Pixel" X (first value)
|
||||
- part measurement width too low?
|
||||
|
|