diff --git a/Calibration.md b/Calibration.md index 9ee8928..6b6bb92 100644 --- a/Calibration.md +++ b/Calibration.md @@ -8,14 +8,14 @@ - part placed too far to the front? - decrease Y camera position -part measurement width too high? - decrease "Distance/Pixel" X (first value) -part measurement width too low? - increase "Distance/Pixel" X (first value) -part measurement height too high? - decrease "Distance/Pixel" Y (second value) -part measurement height too low? - increase "Distance/Pixel" Y (second value) +- part measurement width too high? + - decrease "Distance/Pixel" X (first value) +- part measurement width too low? + - increase "Distance/Pixel" X (first value) +- part measurement height too high? + - decrease "Distance/Pixel" Y (second value) +- part measurement height too low? + - increase "Distance/Pixel" Y (second value) ## Nozzle calibration