@ -0,0 +1,74 @@
|
|||
Up vision calibration
|
||||
---------------------
|
||||
part placed too far to the right?
|
||||
increase X camera position
|
||||
part placed too far to the left?
|
||||
decrease X camera position
|
||||
part placed too far to the back?
|
||||
increase Y camera position
|
||||
part placed too far to the front?
|
||||
decrease Y camera position
|
||||
|
||||
part measurement width too high?
|
||||
decrease "Distance/Pixel" X (first value)
|
||||
part measurement width too low?
|
||||
increase "Distance/Pixel" X (first value)
|
||||
part measurement height too high?
|
||||
decrease "Distance/Pixel" Y (second value)
|
||||
part measurement height too low?
|
||||
increase "Distance/Pixel" Y (second value)
|
||||
|
||||
Nozzle calibration
|
||||
------------------
|
||||
"NozzleDown"
|
||||
These values calibrate the 0mm depth, e.g. for the PCB this is the level of the PCB holder, the system will automatically add the PCB thickness
|
||||
|
||||
"Down To PCB"
|
||||
1. manually move nozzle 1 over the PCB holder
|
||||
2. click "Nozzle Down"
|
||||
3. nozzle 1 should just touch the PCB holder
|
||||
4. adjust Z value of "Down To PCB"
|
||||
5. repeat from 2. until done, else click "Nozzle Up"
|
||||
|
||||
"Down To Stack"
|
||||
1. manually move nozzle 1 over a pick position of a tape feeder stack (ideally no.1 of the left stack), no tape inserted
|
||||
2. click "Nozzle Down"
|
||||
3. nozzle 1 should just touch the metal surface of the pick position
|
||||
4. adjust Z value of "Down To Stack"
|
||||
5. repeat from 2. until done, else click "Nozzle Up"
|
||||
|
||||
"Down To Front"
|
||||
1. manually move nozzle 1 over a pick position of the front IC stack, no part, just the bare stack where a part would sit
|
||||
2. click "Nozzle Down"
|
||||
3. nozzle 1 should just touch the metal surface of the pick position
|
||||
4. adjust Z value of "Down To Stack"
|
||||
5. repeat from 2. until done, else click "Nozzle Up"
|
||||
|
||||
"Down To Discard"
|
||||
Well, this depends on your discard position and preference.
|
||||
|
||||
"NozzleOffset(X,Y)"
|
||||
1. create a reference, ideally a thin lined cross (like a bullseye)
|
||||
2. "System Config" -> "Nozzle" -> "Measure"
|
||||
3. aim center of cross with down vision
|
||||
4. click "Reference" "SetXY"
|
||||
5. move nozzle 1 exactly to the center of the cross, lowering the nozzle onto the cross surface
|
||||
6. click "Nozzle alignment reference point" "Nozzle1:" "SetXY"
|
||||
7. move nozzle 2 exactly to the center of the cross, lowering the nozzle onto the cross surface
|
||||
8. click "Nozzle alignment reference point" "Nozzle2:" "SetXY"
|
||||
9. click "Save"
|
||||
|
||||
Prick calibration
|
||||
-----------------
|
||||
1. choose vision mode
|
||||
2. down vision aim part at pick position, click "Set XY"
|
||||
this uses always the same button:
|
||||
3. click "Prick MoveTo"
|
||||
4. click "Prick Comp" - this will move the tape one component
|
||||
5. click "Nozzle MoveTo" - this will move nozzle 1 down to the component,
|
||||
nozzle should sit on center of component, if not:
|
||||
a) too far left: decrease "PrickOffset" X
|
||||
b) too far right: increase "PrickOffset" X
|
||||
c) prick does not land in tape hole, too far to the back: decrease "PrickOffset" Y
|
||||
c) prick does not land in tape hole, too far to the front: increase "PrickOffset" Y
|
||||
6. repeat from 3. until nozzle lands in center of part
|
Loading…